Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8509328

- Product Categories
- Friendly Links
Information Name: | The VERTEX giant Novo VD2603 thermostat |
Published: | 2011-08-16 |
Validity: | 365 |
Specifications: | Power supply voltage: AC 90 ~ 264V 50 / 60Hz; DC 24V |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | VT26 series microcomputer Fuzzy Enhanced PID controller New features: 1 time alerts. (2) single-stage slope control (3) the output soft-start control. Standard: A various types of thermocouple, RTD input signal selection. 2.FUZZY enhanced PID control (3) Automatic / manual control switch. 4 with two groups of alarms, each set of eight modes are free to plan. Five single-segment slope PID control. 6. Output soft-start function. Full range of power supply voltage 90 to 264VAC 50/60Hz input. Optional: Select a DC linear signal input. The second group output (cooling). 3.4 ~ 20mA setpoint / actual value transfer. 4.VT26 series with 4 ~ 20mA external setpoint input (SP-2). Master-slave transmission (machine tool tape machine) 6.RS-485 communication function (MODBUSRTU format) Supply voltage DC24V power input. >> Specifications: Specifications Enter Thermocouple: JKTEBRSNC Platinum thermal resistance: DIN PT-100; JIS PT-100 Linear signal: 4 ~ 20mA, 0 ~ 50mV, 1 ~ 5V, 0 ~ 10V ┅ Precision thermocouple ± 1 ° C; Platinum thermal resistance ± 0.2 ° C; linear signal ± 3μV Sampling time of 0.5 seconds Proportional Band: 0.0 to 300.0% FS Integration time: 0 ~ 3600 sec. Derivative time: 0 ~ 900 sec. Not with a sense of: 0.0 ~ 200.0 or 0 ~ 2000 Control cycle: 0 ~ 100 sec. Output cycle (0 to 100) relay: 15 seconds 1 second pulse voltage (SSR): Linear current (pressure): 0 seconds Output relay: 10A / 240 VAC (resistive load) Pulse voltage (SSR): DC 0/24V (Resistive load 250Ω) Linear current: 4 ~ 20mA (resistive load 600Ω) Line voltage: 0 ~ 50mV, 1 ~~ 5V, 0 ~ 10V (Resistive load more than 600 Ω) General Specifications Operating ambient temperature: 0 ~ 50 ° C Operating Humidity: 0 ~ 90% Power consumption: 5VA Enter the type and scope of Species range J -50 ° C ~ 1000 ° C -58 ~ 1832 K, -50 ° C ~ 1370 ° C -58 ~ 2498 -270 ℃ ~ 400 ℃ -454 to 752 -50 ℃ ~ 750 ℃ ??-58 ~ 1382 0 ℃ to 1800 ℃ 32 ~ 3272 R 0 ℃ ~ 1750 ℃ ??32 ~ 3182 S-0 ° C to 1750 ° C 32 ~ 3182 N -50 ℃ ~ 1300 ℃ -58 ~ 2 372 -50 ℃ ~ 1800 ℃ -58 ~ 3 272 Of DPT -200 ℃ ~ 850 ℃ -328 1 652 Of JPT -200 ℃ ~ 650 ℃ -328 to 1202 The LINE -1999 ~ 9999 Alarm mode Absolute upper limit alarm Absolute lower limit alarm Maximum deviation alarm deviation value lower limit alarm Alarm within the region Outside the region alerts Absolute upper limit of delay alarm Absolute lower limit of delay alarm Related Products: the VERTEX Thermostat VT4810 VT4910 VT7210 VT9610 VT4820 VT4920 VT7220 VT9620 VT4830 VT4930 VT7230 VT9630 VT4826 VT4926 VT7226 VT9626 VT9621 VD2001 VD2002 VD2003 VD2600 VD2601 VD2603 VD2604 |
Admin>>>
You are the 9670 visitor
Copyright © GuangDong ICP No. 10089450, Instrument Co., Ltd., Dongguan City, Oceanside All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 9670 visitor
Copyright © GuangDong ICP No. 10089450, Instrument Co., Ltd., Dongguan City, Oceanside All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility